The RM-DPC Micro units from the SensorLine range are differential pressure controllers for application in harsh industrial environments. They are used to measure, visualize and control non-corrosive gaseous media in above atmospheric and negative pressure ranges.
All necessary functions can be easily configured and displayed with the backlit text display and 2-key menu control. In the operating mode, the 32-characters text display shows the differential pressure with selectable physical unit as well as service and alarm messages. Additionally, the states ON / SERVICE / ALARM are indicated by LEDs.
Apart from the controller functions, also the on-off controller, time functions, operating and service hours counters can be configured by the software. The measuring range can be configured by a program parameter that automatically sets the output signals for the differential pressure to the desired range. Thanks to these functions, the differential pressure controller can be used for a variety of applications.
For customer-specific applications, the in-system function can be used to easily add, edit or extend software modules. On request, further sensors are available for special measuring ranges.
For an optimal application, the differential pressure controller is available in two versions: RM-DPC Micro and RM-DPC Micro FP. The RM-DPC Micro devices are designed for wall mounting in a NormLine-S box. The RM-DPC Micro FP devices are designed for panel mounting in a front panel. Both device versions are also available for Ex areas acc. to ATEX zone 22, cat. 3D. The explosion proof versions are approved by DEKRA-EXAM.
| System | In-system programmable processor system, piezoresistive measuring bridge |
|---|---|
| Prüfungen |
RM-DPC Micro: Box from polycarbonate in RAL 7035, IP 66 / NEMA 4 / IK08 RM-DPC Micro FP: Front panel from polycarbonate, transparent, IP-66 |
| RM-DPC Micro ATEX: Box from polycarbonate in RAL 5015, IP 66 / NEMA 4 / IK08
ATEX Zone 22, BVS 03 E 141 RM-DPC Micro FP ATEX: Front panel from polycarbonate, transparent, IP-66 ATEX Zone 22, BVS 03 E 141 |
|
| Normen/Konformität | EN 50178, EN 60.439 Part 500, VDE 0160, 2004/108/EC |
| No. | Function | Description |
|---|---|---|
| On-off differential pressure controller | Differential pressure control by the switch points DP-Min and DP-Max | |
| Δp monitoring | Alarm switch points DP-Min Alarm and DP-Max Alarm | |
| Forced cleaning | Configurable pause time for the forced cleaning | |
| Special functions configurable by software | Special functions on customer‘s request | |
| Supply voltage | RM-DPC Micro / RM-DPC Micro ATEX: 230 V AC, 110 V AC ±10%, 50-60 Hz 24 V DC +10% / -0% RM-DPC Micro FP / RM-DPC Micro FP ATEX: 24 V DC +10% / -0% |
|
| Differential pressure signal outputs | 4-20 mA (0-20 mA) / 2-10 V (0-10 V) | |
| 4-20mA signal inputs | to connect an external sensor (passive or active) | |
| Signal output Differential pressure controller |
C/O relay contact Max. contact rating: 250 V AC, 10 A / 30 V DC, 10 A (ohmic load) |
|
| Signal output Differential pressure min. alarm |
N/O relay contact Max. contact rating: 250 V AC, 10 A / 30 V DC, 10 A (ohmic load) |
|
| Signal output Differential pressure max. alarm |
N/O relay contact Max. contact rating: 250 V AC, 10 A / 30 V DC, 10 A (ohmic load) |
|
| ON LED | Signalizes the device‘s readiness for operation | |
| Service LED | Signalizes a due maintenance of the filter | |
| Alarm LED | Signalizes an alarm | |
| Clear text display | Backlit LC display, 2x16 characters | |
| 2-key menu control | ![]() |
| Technische Daten | RM-DPC 5000 Micro RM-DPC 5000 Micro ATEX RM-DPC 5000 Micro FP RM-DPC 5000 Micro FP ATEX |
RM-DPC 10000 Micro RM-DPC 10000 Micro ATEX RM-DPC 10000 Micro FP RM-DPC 10000 Micro FP ATEX |
||||
|---|---|---|---|---|---|---|
| Sensor measuring range | 0 ... 5000 Pa | 0 ... 10000 Pa | ||||
| Configurable measuring range | For the range 1000 Pa ... 5000 Pa End value configurable in steps of 500 Pa |
For the range 1000 Pa ... 5000 Pa End value continuously configurable |
||||
| Output signal corresponding to the set measuring range |
4-20 mA (0-20 mA) 2-10 V (0-10 V) |
≙ | set measuring range |
4-20 mA (0-20 mA) 2-10 V (0-10 V) |
≙ | set measuring range |
| Full scale output (FSO) | 5000 Pa | 10000 Pa | ||||
| Accuracy (linearity and hysteresis) |
≤ ± 1 %FSO* ≙ ≤ ± 50 Pa | ≤ ± 1 %FSO* ≙ ≤ ± 100 Pa | ||||
| One-side overpressure safety | 138 kPa | |||||
| Response time | 11 ms | |||||
| Burden | ≤ 600 Ω | |||||
| Pressurised medium | Air and non-corrosive gases | |||||
| Process connection | RM-DPC Micro / RM-DPC Micro ATEX: 6/4 mm hose socket RM-DPC Micro FP / RM-DPC Micro FP ATEX: 4/2 mm hose socket |
|||||
| Ambient temperature range | -20 to +60°C | |||||
| Humidity range of ambient air | 0 ... 95 % relative humidity of air, non-condensing | |||||
| Altitude | Up to 3000 m above sea level | |||||
| Product | P/N |
|---|---|
| RM-DPC 5000 Micro | 10602300 |
| RM-DPC 10000 Micro | 10602304 |
| RM-DPC 5000 Micro ATEX | 10602301 |
| RM-DPC 10000 Micro ATEX | 10602305 |
| RM-DPC 5000 Micro FP | 10602400 |
| RM-DPC 10000 Micro FP | 10602401 |
| RM-DPC 5000 Micro FP ATEX | 10602404 |
| RM-DPC 10000 Micro FP ATEX | 10602405 |
Special measuring ranges and functions are possible on customer request.