SensorLine

Differential pressure controller RM-DPC Micro

Function

The RM-DPC Micro units from the SensorLine range are differential pressure controllers for application in harsh industrial environments. They are used to measure, visualize and control non-corrosive gaseous media in above atmospheric and negative pressure ranges.

All necessary functions can be easily configured and displayed with the backlit text display and 2-key menu control. In the operating mode, the 32-characters text display shows the differential pressure with selectable physical unit as well as service and alarm messages. Additionally, the states ON / SERVICE / ALARM are indicated by LEDs.

Apart from the controller functions, also the on-off controller, time functions, operating and service hours counters can be configured by the software. The measuring range can be configured by a program parameter that automatically sets the output signals for the differential pressure to the desired range. Thanks to these functions, the differential pressure controller can be used for a variety of applications.

For customer-specific applications, the in-system function can be used to easily add, edit or extend software modules. On request, further sensors are available for special measuring ranges.

Types

For an optimal application, the differential pressure controller is available in two versions: RM-DPC Micro and RM-DPC Micro FP. The RM-DPC Micro devices are designed for wall mounting in a NormLine-S box. The RM-DPC Micro FP devices are designed for panel mounting in a front panel. Both device versions are also available for Ex areas acc. to ATEX zone 22, cat. 3D. The explosion proof versions are approved by DEKRA-EXAM.


Technical specifications

System In-system programmable processor system, piezoresistive measuring bridge
Prüfungen
DEKRA TÜV
RM-DPC Micro: Box from polycarbonate in RAL 7035, IP 66 / NEMA 4 / IK08
RM-DPC Micro FP: Front panel from polycarbonate, transparent, IP-66
RM-DPC Micro ATEX: Box from polycarbonate in RAL 5015, IP 66 / NEMA 4 / IK08 ATEX Zone 22, BVS 03 E 141
RM-DPC Micro FP ATEX: Front panel from polycarbonate, transparent, IP-66 ATEX Zone 22, BVS 03 E 141
Normen/Konformität EN 50178, EN 60.439 Part 500, VDE 0160, 2004/108/EC
RM-DPC Micro
No. Function Description
  On-off differential pressure controller Differential pressure control by the switch points DP-Min and DP-Max
  Δp monitoring Alarm switch points DP-Min Alarm and DP-Max Alarm
  Forced cleaning Configurable pause time for the forced cleaning
  Special functions
configurable by software
Special functions on customer‘s request
1 Supply voltage RM-DPC Micro / RM-DPC Micro ATEX: 230 V AC, 110 V AC ±10%, 50-60 Hz 24 V DC +10% / -0%
RM-DPC Micro FP / RM-DPC Micro FP ATEX: 24 V DC +10% / -0%
2 Differential pressure signal outputs 4-20 mA (0-20 mA) / 2-10 V (0-10 V)
3 4-20mA signal inputs to connect an external sensor (passive or active)
4 Signal output
Differential pressure controller
C/O relay contact
Max. contact rating: 250 V AC, 10 A / 30 V DC, 10 A (ohmic load)
5 Signal output
Differential pressure min. alarm
N/O relay contact
Max. contact rating: 250 V AC, 10 A / 30 V DC, 10 A (ohmic load)
6 Signal output
Differential pressure max. alarm
N/O relay contact
Max. contact rating: 250 V AC, 10 A / 30 V DC, 10 A (ohmic load)
ON LED Signalizes the device‘s readiness for operation
8 Service LED Signalizes a due maintenance of the filter
9 Alarm LED Signalizes an alarm
10 Clear text display Backlit LC display, 2x16 characters
11 2-key menu control
Technische Daten RM-DPC 5000 Micro
RM-DPC 5000 Micro ATEX
RM-DPC 5000 Micro FP
RM-DPC 5000 Micro FP ATEX
RM-DPC 10000 Micro
RM-DPC 10000 Micro ATEX
RM-DPC 10000 Micro FP
RM-DPC 10000 Micro FP ATEX
Sensor measuring range 0 ... 5000 Pa 0 ... 10000 Pa
Configurable measuring range For the range 1000 Pa ... 5000 Pa
End value configurable in steps of 500 Pa

For the range 1000 Pa ... 5000 Pa
End value configurable in steps of 500 Pa

For the range 5000 Pa ... 10000 Pa
End value continuously configurable
Output signal corresponding to
the set measuring range
4-20 mA (0-20 mA)
2-10 V (0-10 V)
set measuring
range
4-20 mA (0-20 mA)
2-10 V (0-10 V)
set measuring
range
Full scale output (FSO) 5000 Pa 10000 Pa
Accuracy
(linearity and hysteresis)
≤ ± 1 %FSO* ≙ ≤ ± 50 Pa ≤ ± 1 %FSO* ≙ ≤ ± 100 Pa
One-side overpressure safety 138 kPa
Response time 11 ms
Burden ≤ 600 Ω
Pressurised medium Air and non-corrosive gases
Process connection RM-DPC Micro / RM-DPC Micro ATEX: 6/4 mm hose socket
RM-DPC Micro FP / RM-DPC Micro FP ATEX: 4/2 mm hose socket
Ambient temperature range -20 to +60°C
Humidity range of ambient air 0 ... 95 % relative humidity of air, non-condensing
Altitude Up to 3000 m above sea level


Dimension drawings



Product selection

Product P/N
RM-DPC 5000 Micro 10602300
RM-DPC 10000 Micro 10602304
RM-DPC 5000 Micro ATEX 10602301
RM-DPC 10000 Micro ATEX 10602305
RM-DPC 5000 Micro FP 10602400
RM-DPC 10000 Micro FP 10602401
RM-DPC 5000 Micro FP ATEX 10602404
RM-DPC 10000 Micro FP ATEX 10602405


Special measuring ranges and functions are possible on customer request.