The RM-BV12 from the BasicLine range is a filter controller in modular design with extendable functionalities for small and medium-sized filter systems with pulse cleaning up to 12 valves in harsh industrial environments.
On the basic model RM-BV 12, all necessary functions - number of valves, valve opening time, pause time and downtime cleaning - can be easily set by selector switches. Key operational conditions of the units - monitoring of the supply and valve voltages, short-circuit monitoring of the valve outputs - are signalled as alarms via the potential-free relay outputs. Additionally, the unit can be externally started and stopped via signal inputs. The states ON / STOP / ALARM / VALVE OUTPUT 1-12 are indicated by LEDs. In the explosion proof version with integrated solenoid valves, a temperature sensor monitors the controller and cuts off the unit in the case of a malfunction.
For an extension of the functionalities, the RM-DPC differential pressure control module can be plugged on the basic unit. Among others, a cleaning as a function of the differential pressure and a differential pressure monitoring can then be configured. All necessary functions can be easily configured and displayed with the backlit text display and 2-key menu control. In the operating mode, the 32-characters text display shows the differential pressure with selectable physical unit, the cleaning function as well as service and alarm messages. Additionally, the states ON / SERVICE / ALARM are indicated by LEDs.
All functions of the differential pressure guard/controller and filter controller can be configured and extended by software.
Devices for wall mounting are accommodated in a NormLine box and can be equipped with up to 10 solenoid valves in this version. If more valves are necessary, another NormLine box with integrated valves can be mounted on the flange. As an alternative, the control system can be extended with valve boxes from the RECO range (V boxes / ComponentLine). The devices are also available with mounting frame for rail mounting. For an outdoor installation up to an outside temperature of -45 °C, the RM-BV 12 can be equipped with a controlled valve heating that is supplied from the device’s transformer. All versions are also available for the ATEX zone 22, cat. 3D, and are DEKRA EXAM approved.
| System | In-system programmable processor system |
|---|---|
| Tests |
RM-BV 12 / RM-BV 12 DP NormLine box from polycarbonate in RAL 7035, IP66 / NEMA 4 / IK08 |
| RM-BV 12 ATEX / RM-BV 12 DP ATEX BlueLine box from polycarbonate in RAL 5015, IP-66 / NEMA 4 / IK08 ATEX Zone 22, BVS 03 E 141 / II 3 D IP 66 T85 °C Temperature monitoring of the integrated solenoid valves |
|
| Solenoid valves that can be built in | 1 ... 10 valves can be integrated in the BlueLine box / up to 12 valves with flangemounted valve box / 2/2-port directional valves with 6mm push-fit hose connection / control pressure 2 ... 7 bar / 24 V DC, 22 W, duty cycle 10 % |
| Norms / Conformity | EN 50178, EN 60.439 Part 500, VDE 0160, 2004/108/EC |
| No. | Function | Description |
|---|---|---|
| Supply voltage | 230 V AC ± 10%, 50-60 Hz / 110 V AC ± 10%, 50-60 Hz or 24 V ... 30 V DC | |
| Valve outputs | 12 short-circuit proof outputs, 24 V DC, max. 1.9 A | |
| Start input | Optocoupler, 24 V DC | |
| Stop input | ||
| Cleaning output | C/O relay contact Max. contact rating: 250 V AC, 10 A; 30 V DC, 10 A (ohmic load) |
|
| Alarm output | ||
| LED "ON" | Signalizes the applied operating voltage and the downtime | |
| LED "Stop" | Signalizes the active „Stop“ input | |
| "Valves 1 - 12" LED | Signalizes the active output | |
| Selector switch S1 | Number of valves: 1 - 12 | |
| Selector switch S2 | Valve opening time [ms] 40, 50, 60, 70, 80, 100, 120, 140, 160, 180, 200, 220, 250, 300, 350, 400 |
|
| Selector switch S3 | Pause time [s] 2, 5, 8, 10, 12, 16, 20, 25, 30, 35, 40, 50, 60, 80, 100, 120 |
|
| Selector switch S4 | Downtime cleaning in cleaning cycles 0 through 15 | |
| Plug connector for the RM-DPC module | Plug connector to connect the RM-DPC module to the base board (see figure) | |
| Clear text display | Backlit LC display, 2x16 characters | |
| LED "ON" | Signalizes the device‘s readiness for operation | |
| LED "Service" | Signalizes a due maintenance of the filter | |
| LED "Alarm" | Signalizes an alarm | |
| 2-key menu control | ![]() |
|
| Alarm output | Relay contact (the function can be set by the parameter 12) Max. contact rating: 250 V AC, 10 A; 30 V DC, 10 A (ohmic load) |
|
| Differential pressure signal outputs | 4-20 mA correspond 0 ... 5000 Pa | |
| Internal differential pressure connection | When retrofitting the RM-DPC module, the differential pressure connector screwed in the box needs to be connected to the internal connector by means of two hose pieces (4/2 mm, 145 mm). | |
| Option Ventilheizung | Integrated valve heating with on-off control for RECO valve types RM-NG 4 and RM-N 4.5. ON at ϑ < 3°C / OFF at ϑ > 15°C |
| Product | P/N | integrated valves |
RM-DPC module |
Valve heating |
Dust Ex Zone 22 |
|
|---|---|---|---|---|---|---|
| 230 V AC / 110 V AC | 24 V DC | |||||
| RM-BV 12 | 10603205 | 10603206 | 0 | - | - | - |
| RM-BV 12 1V | 10603207 | 10603208 | 1 | - | - | - |
| RM-BV 12 2V | 10603209 | 10603210 | 2 | - | - | - |
| RM-BV 12 3V | 10603211 | 10603212 | 3 | - | - | - |
| RM-BV 12 4V | 10603213 | 10603214 | 4 | - | - | - |
| RM-BV 12 5V | 10603215 | 10603216 | 5 | - | - | - |
| RM-BV 12 6V | 10603217 | 10603218 | 6 | - | - | - |
| RM-BV 12 7V | 10603219 | 10603220 | 7 | - | - | - |
| RM-BV 12 8V | 10603221 | 10603222 | 8 | - | - | - |
| RM-BV 12 9V | 10603223 | 10603224 | 9 | - | - | - |
| RM-BV 12 10V | 10603225 | 10603226 | 10 | - | - | - |
| RM-BV 12 DP | 10603227 | 10603228 | 0 | - | - | |
| RM-BV 12 DP 1V | 10603229 | 10603230 | 1 | - | - | |
| RM-BV 12 DP 2V | 10603231 | 10603232 | 2 | - | - | |
| RM-BV 12 DP 3V | 10603233 | 10603234 | 3 | - | - | |
| RM-BV 12 DP 4V | 10603235 | 10603236 | 4 | - | - | |
| RM-BV 12 DP 5V | 10603237 | 10603238 | 5 | - | - | |
| RM-BV 12 DP 6V | 10603239 | 10603240 | 6 | - | - | |
| RM-BV 12 DP 7V | 10603241 | 10603242 | 7 | - | - | |
| RM-BV 12 DP 8V | 10603243 | 10603244 | 8 | - | - | |
| RM-BV 12 DP 9V | 10603245 | 10603246 | 9 | - | - | |
| RM-BV 12 10V | 10603247 | 10603248 | 10 | - | - | |
| RM-BV 12 Heating | 10603249 | 10603250 | 0 | - | - | |
| RM-BV 12 1V Heating | 10603251 | 10603252 | 1 | - | - | |
| RM-BV 12 2V Heating | 10603253 | 10603254 | 2 | - | - | |
| RM-BV 12 3V Heating | 10603255 | 10603256 | 3 | - | - | |
| RM-BV 12 4V Heating | 10603257 | 10603258 | 4 | - | - | |
| RM-BV 12 5V Heating | 10603259 | 10603260 | 5 | - | - | |
| RM-BV 12 6V Heating | 10603261 | 10603262 | 6 | - | - | |
| RM-BV 12 7V Heating | 10603263 | 10603264 | 7 | - | - | |
| RM-BV 12 8V Heating | 10603265 | 10603266 | 8 | - | - | |
| RM-BV 12 9V Heating | 10603267 | 10603268 | 9 | - | - | |
| RM-BV 12 10V Heating | 10603269 | 10603270 | 10 | - | - | |
| RM-BV 12 DP ATEX | 10603271 | 10603272 | 0 | - | ||
| RM-BV 12 DP 1V ATEX | 10603273 | 10603274 | 1 | - | ||
| RM-BV 12 DP 2V ATEX | 10603275 | 10603276 | 2 | - | ||
| RM-BV 12 DP 3V ATEX | 10603277 | 10603278 | 3 | - | ||
| RM-BV 12 DP 4V ATEX | 10603279 | 10603280 | 4 | - | ||
| RM-BV 12 DP 5V ATEX | 10603281 | 10603282 | 5 | - | ||
| RM-BV 12 DP 6V ATEX | 10603283 | 10603284 | 6 | - | ||
| RM-BV 12 DP 7V ATEX | 10603285 | 10603286 | 7 | - | ||
| RM-BV 12 DP 8V ATEX | 10603287 | 10603288 | 8 | - | ||
| RM-BV 12 DP 9V ATEX | 10603289 | 10603290 | 9 | - | ||
| RM-BV 12 10V ATEX | 10603291 | 10603292 | 10 | - | ||
| RM-BV 12 Heating ATEX | 10603293 | 10603294 | 0 | - | ||
| RM-BV 12 1V Heating ATEX | 10603295 | 10603296 | 1 | - | ||
| RM-BV 12 2V Heating ATEX | 10603297 | 10603298 | 2 | - | ||
| RM-BV 12 3V Heating ATEX | 10603299 | 10603300 | 3 | - | ||
| RM-BV 12 4V Heating ATEX | 10603301 | 10603302 | 4 | - | ||
| RM-BV 12 5V Heating ATEX | 10603303 | 10603304 | 5 | - | ||
| RM-BV 12 6V Heating ATEX | 10603305 | 10603306 | 6 | - | ||
| RM-BV 12 7V Heating ATEX | 10603307 | 10603308 | 7 | - | ||
| RM-BV 12 8V Heating ATEX | 10603309 | 10603310 | 8 | - | ||
| RM-BV 12 9V Heating ATEX | 10603311 | 10603312 | 9 | - | ||
| RM-BV 12 10V Heating ATEX | 10603313 | 10603314 | 10 | - | ||
| Product | P/N | integrated valves |
RM-DPC module |
Valve heating |
Dust Ex Zone 22 |
|
|---|---|---|---|---|---|---|
| 230 V AC / 110 V AC | 24 V DC | |||||
| RM-BV 12 | 10603315 | 10603316 | 0 | - | - | - |
| Product | P/N |
|---|---|
| RM-DPC Modul | 10603317 |
| Product | P/N | integrated valves |
RM-DPC module |
Valve heating |
Dust Ex Zone 22 |
|
|---|---|---|---|---|---|---|
| 230 V AC / 110 V AC | 24 V DC | |||||
| RM-BV 12 11V | 10603320 | 10603321 | 11 | - | - | - |
| RM-BV 12 12V | 10603322 | 10603323 | 12 | - | - | - |
| RM-BV 12 DP 11V | 10603324 | 10603325 | 11 | - | - | |
| RM-BV 12 DP 12V | 10603326 | 10603327 | 12 | - | - | |
| RM-BV 12 11V ATEX | 10603328 | 10603329 | 11 | - | - | |
| RM-BV 12 12V ATEX | 10603330 | 10603331 | 12 | - | - | |
| RM-BV 12 DP 11V ATEX | 10603332 | 10603333 | 11 | - | ||
| RM-BV 12 DP 12V ATEX | 10603334 | 10603335 | 12 | - | ||
| Product | P/N | integrated valves |
RM-DPC module |
Valve heating |
Dust Ex Zone 22 |
|
|---|---|---|---|---|---|---|
| 230 V AC / 110 V AC | 24 V DC | |||||
| RM-BV 12 6V | 10603336 | 10603337 | 6 | - | - | - |
| RM-BV 12 DP 6V | 10603338 | 10603339 | 6 | - | - | |
| RM-BV 12 6V ATEX | 10603340 | 10603341 | 6 | - | - | |
| RM-BV 6 DP 6V ATEX | 10603342 | 10603343 | 6 | - | ||
| V-Box 5V | 10603344 | 5 | - | - | - | |
| V-Box 6V | 10603345 | 6 | - | - | - | |
| V-Box 5V ATEX | 10603346 | 5 | - | - | ||
| V-Box 6V ATEX | 10603347 | 6 | - | - | ||
For more valve boxes see the separate "CleaningLine" product overview.