The filter controllers RM-208 C / ...CB and RM-216 C / ...CB from the EasyLine range have a Loop bus interface for the control of the extension modules RM-LV8 / ...16 for use in filter systems with pulse cleaning and up to 128 valves in harsh industrial environments.
A 32-character text display and a 3-key menu control on the controllers can be used to set and view diverse operating modes and control functions in an easy and convenient manner. In operating mode, the text display indicates all current status messages and control functions. Additionally, the states ON / SERVICE / ALARM are indicated by LEDs. Via the Loop Bus interface, it is possible to control a maximum of 7 extension modules from the different controllers. Important operating characteristics of the controllers – monitoring of the supply and valve voltage, valve output short-circuit monitoring, alarms and Loop Bus function monitoring – are signalled via potential-free relay outputs as alarms. In the ATEX version for the dust ex zone 22 with integrated solenoid valves RM-NG 4, a temperature sensor monitors the controllers and cuts off the devices in case of malfunction.
More than 160 software modules from the filter technology can be chosen for additional functions or customer-specific applications. With the in-system programming, they can be easily added, modified and extended.
The RM-208 CB / ...216 CB controllers are basic versions without differential pressure sensor. The RM-208 C / ...216 C controllers are equipped with a differential pressure sensor. All device versions, controllers and extension modules, are available in the RECO NormLine box for wall mounting.
The RM-208C / ...CB controllers and the RM-LV 8 / ...16 extension modules can also be built in NormLine boxes with integrated RM-NG 4 solenoid valves. These devices are also available in a mounting frame for DIN rail mounting. In this version, the controllers are delivered with the separate RM-VISIO 32 operating and visualization panel.
For further options, the NormLine boxes can also be mounted to each other by flanges to build a functional unit. Another extension option is the connection of separate RECO V boxes from the ComponentLine range.
All versions are also available for Ex areas acc. to ATEX Dust Ex Zone 22.



| System | In-system programmable processor system |
|---|---|
| Tests |
NormLine box from polycarbonate in RAL 7035, IP66 / NEMA 4 / IK08 |
| Solenoid valves that can be built in | 1 ... 8 valves can be integrated in the NormLine box / up to 16 valves with flange-mounted valve box / 2/2-port directional valves with 6mm push-fit hose connection / control pressure 2 ... 7 bar / 24 V DC, 22 W, duty cycle 10% |
| Norms / Conformity | EN 50178, EN 60.439 Part 500, VDE 0160, 2004/108/EC |
| No. | Function | Description |
|---|---|---|
| Supply voltage | 230 V AC ±10%, 50-60 Hz / 110 V AC ±10%, 50-60 Hz / 26 V ... 28 V DC 230 V AC ±10%, 50-60 Hz / 110 V AC ±10%, 50-60 Hz or 26 V ... 28 V DC |
|
| „Group alarm“ output | C/O relay contact Max. contact rating: 250 V AC, 10 A; 30 V DC, 10 A (ohmic load) |
|
| „Discharge device“ output | Connection of the contactor coil for the control of the discharge device in the downtime | |
| „Downtime cleaning“ input | Fan start/stop signal input | |
| „Start/stop“ input | Connection of an external Δp-switch | |
| „Δp Max. Alarm“ output | N/O relay contact Max. contact rating: 250 V AC, 10 A; 30 V DC, 10 A (ohmic load) |
|
| Valve outputs | RM-208 C: 8 short-circuit proof outputs, 24 V DC, max. 1.9 A RM-216 C: 16 short-circuit proof outputs, 24 V DC, max. 1.9 A |
|
| Control loop for extension module | Connection of the extension modules RM-LV 8 (8 valves) and RM-LV 16 (16 valves) | |
| „Differential pressure“ output (4-20mA) | Connection of a remote differential pressure display | |
| „Differential pressure“ input (4-20mA) | Connection of an external differential pressure sensor – optional | |
| Control and display panel | RJ45 port to connect the control and display panel in the box cover | |
| Differential pressure sensor | Sensor for capturing the differential pressure on the filter (not applicable for the RM-208 CB and RM-216 CB models) |

| Meaning | Factory setting | Setting range | |
|---|---|---|---|
| Δp MIN switch point | 700 Pa | 260 Pa ... 4000 Pa | - |
| Δp MAX switch point | 1300 Pa | 280 Pa ... 4400 Pa | - |
| Δp alarm switch point | 2300 Pa | 300 Pa ... 5000 Pa | - |
| Pulse Time | 60 ms | 30 ms ... 300 ms | PES2 |
| Interval Time | 10 s | 4 s ... 500 s | - |
| Down time interval (DTC = down time cleaning) |
6 s | 2 s ... 100 s | - |
| Total no. of valves (main and ancillary devices) |
0 | 0 ... 128 | PES2 |
| Downtime cleaning cycles | 6 | 0 ... 32 | PES2 |
| Parameters for downtime activation (DTC modes 2 and 3) |
1000 Pa | 280 Pa ... 4000 Pa | PES2 |
| Parameter for activation of the downtime (DTC mode 3) |
260 Pa | 260 Pa ... 2000 Pa | PES2 |
| Hours in operation | - | 0 ... 250.000 h | SBC3 |
| Language of display text | D | D, GB, F, I, NL, DK, FIN, PL | - |
| Δp unit | Pa | Pa, mbar, Inch WC, mm WG | - |
| Downtime cleaning mode (DTC mode) |
2 | 1 ... 3 | PES2 |
| Test operation (0 = test operation off /_1 = valve test / 2 = input test) |
01 | 01 ... 7 | - |
| Δp range | 0 ... 5000 Pa | 0 ... 1000 Pa to 0 ... 5000 Pa |
- |
| Resets the service hours in the operation counter to 0 |
- | - | SBC3 |
| Service/operating hours alarm | 01 | 01 ... 25.000 h | SBC3 |
| Service/operating hours code | 0 | - | PES2 |
| Differential pressure mode | On | On, Off | - |
| Parameter setting lock | On | On, Off | - |
1 0 = disabled
2 The parameter is factoryprotected by the parameter setting lock.
3 The parameter can only be changed when the service/operating hours code has been entered.

| Product | Dust Ex Zone 22 |
Δp- sensor |
Number of valves |
P/N | ||
|---|---|---|---|---|---|---|
| RM-208 C | 230 V AC / 110 V AC | - | |
0 | 16000380 | |
| RM-208 C – 1 V | 230 V AC / 110 V AC | - | |
1 | 16000381 | |
| RM-208 C – 2 V | 230 V AC / 110 V AC | - | |
2 | 16000382 | |
| RM-208 C – 3 V | 230 V AC / 110 V AC | - | |
3 | 16000383 | |
| RM-208 C – 4 V | 230 V AC / 110 V AC | - | |
4 | 16000384 | |
| RM-208 C – 5 V | 230 V AC / 110 V AC | - | |
5 | 16000385 | |
| RM-208 C – 6 V | 230 V AC / 110 V AC | - | |
6 | 16000386 | |
| RM-208 C – 7 V | 230 V AC / 110 V AC | - | |
7 | 16000387 | |
| RM-208 C – 8 V | 230 V AC / 110 V AC | - | |
8 | 16000388 | |
| RM-208 CB | 230 V AC / 110 V AC | - | - | 0 | 16000400 | |
| RM-208 CB – 1 V | 230 V AC / 110 V AC | - | - | 1 | 16000401 | |
| RM-208 CB – 2 V | 230 V AC / 110 V AC | - | - | 2 | 16000402 | |
| RM-208 CB – 3 V | 230 V AC / 110 V AC | - | - | 3 | 16000403 | |
| RM-208 CB – 4 V | 230 V AC / 110 V AC | - | - | 4 | 16000404 | |
| RM-208 CB – 5 V | 230 V AC / 110 V AC | - | - | 5 | 16000405 | |
| RM-208 CB – 6 V | 230 V AC / 110 V AC | - | - | 6 | 16000406 | |
| RM-208 CB – 7 V | 230 V AC / 110 V AC | - | - | 7 | 16000407 | |
| RM-208 CB – 8 V | 230 V AC / 110 V AC | - | - | 8 | 16000408 | |
| RM-208 C | 24 V DC | - | |
0 | 16000460 | |
| RM-208 C – 1 V | 24 V DC | - | |
1 | 16000461 | |
| RM-208 C – 2 V | 24 V DC | - | |
2 | 16000462 | |
| RM-208 C – 3 V | 24 V DC | - | |
3 | 16000463 | |
| RM-208 C – 4 V | 24 V DC | - | |
4 | 16000464 | |
| RM-208 C – 5 V | 24 V DC | - | |
5 | 16000465 | |
| RM-208 C – 6 V | 24 V DC | - | |
6 | 16000466 | |
| RM-208 C – 7 V | 24 V DC | - | |
7 | 16000467 | |
| RM-208 C – 8 V | 24 V DC | - | |
8 | 16000468 | |
| RM-208 CB | 24 V DC | - | - | 0 | 16000480 | |
| RM-208 CB – 1 V | 24 V DC | - | - | 1 | 16000481 | |
| RM-208 CB – 2 V | 24 V DC | - | - | 2 | 16000482 | |
| RM-208 CB – 3 V | 24 V DC | - | - | 3 | 16000483 | |
| RM-208 CB – 4 V | 24 V DC | - | - | 4 | 16000484 | |
| RM-208 CB – 5 V | 24 V DC | - | - | 5 | 16000485 | |
| RM-208 CB – 6 V | 24 V DC | - | - | 6 | 16000486 | |
| RM-208 CB – 7 V | 24 V DC | - | - | 7 | 16000487 | |
| RM-208 CB – 8 V | 24 V DC | - | - | 8 | 16000488 | |
| Product | Dust Ex Zone 22 |
Δp- sensor |
Number of valves |
P/N | ||
|---|---|---|---|---|---|---|
| RM-208 C 0 V ATEX | 230 V AC / 110 V AC | |
|
0 | 16000390 | |
| RM-208 C – 1 V ATEX | 230 V AC / 110 V AC | |
|
1 | 16000391 | |
| RM-208 C – 2 V ATEX | 230 V AC / 110 V AC | |
|
2 | 16000392 | |
| RM-208 C – 3 V ATEX | 230 V AC / 110 V AC | |
|
3 | 16000393 | |
| RM-208 C – 4 V ATEX | 230 V AC / 110 V AC | |
|
4 | 16000394 | |
| RM-208 C – 5 V ATEX | 230 V AC / 110 V AC | |
|
5 | 16000395 | |
| RM-208 C – 6 V ATEX | 230 V AC / 110 V AC | |
|
6 | 16000396 | |
| RM-208 C – 7 V ATEX | 230 V AC / 110 V AC | |
|
7 | 16000397 | |
| RM-208 C – 8 V ATEX | 230 V AC / 110 V AC | |
|
8 | 16000398 | |
| RM-208 CB | 230 V AC / 110 V AC | |
- | 0 | 16000410 | |
| RM-208 CB – 1 V ATEX | 230 V AC / 110 V AC | |
- | 1 | 16000411 | |
| RM-208 CB – 2 V ATEX | 230 V AC / 110 V AC | |
- | 2 | 16000412 | |
| RM-208 CB – 3 V ATEX | 230 V AC / 110 V AC | |
- | 3 | 16000413 | |
| RM-208 CB – 4 V ATEX | 230 V AC / 110 V AC | |
- | 4 | 16000414 | |
| RM-208 CB – 5 V ATEX | 230 V AC / 110 V AC | |
- | 5 | 16000415 | |
| RM-208 CB – 6 V ATEX | 230 V AC / 110 V AC | |
- | 6 | 16000416 | |
| RM-208 CB – 7 V ATEX | 230 V AC / 110 V AC | |
- | 7 | 16000417 | |
| RM-208 CB – 8 V ATEX | 230 V AC / 110 V AC | |
- | 8 | 16000418 | |
| RM-208 C 0 V ATEX | 24 V DC | |
|
0 | 16000470 | |
| RM-208 C – 1 V ATEX | 24 V DC | |
|
1 | 16000471 | |
| RM-208 C – 2 V ATEX | 24 V DC | |
|
2 | 16000472 | |
| RM-208 C – 3 V ATEX | 24 V DC | |
|
3 | 16000473 | |
| RM-208 C – 4 V ATEX | 24 V DC | |
|
4 | 16000474 | |
| RM-208 C – 5 V ATEX | 24 V DC | |
|
5 | 16000475 | |
| RM-208 C – 6 V ATEX | 24 V DC | |
|
6 | 16000476 | |
| RM-208 C – 7 V ATEX | 24 V DC | |
|
7 | 16000477 | |
| RM-208 C – 8 V ATEX | 24 V DC | |
|
8 | 16000478 | |
| RM-208 CB | 24 V DC | |
- | 0 | 16000490 | |
| RM-208 CB – 1 V ATEX | 24 V DC | |
- | 1 | 16000491 | |
| RM-208 CB – 2 V ATEX | 24 V DC | |
- | 2 | 16000492 | |
| RM-208 CB – 3 V ATEX | 24 V DC | |
- | 3 | 16000493 | |
| RM-208 CB – 4 V ATEX | 24 V DC | |
- | 4 | 16000494 | |
| RM-208 CB – 5 V ATEX | 24 V DC | |
- | 5 | 16000495 | |
| RM-208 CB – 6 V ATEX | 24 V DC | |
- | 6 | 16000496 | |
| RM-208 CB – 7 V ATEX | 24 V DC | |
- | 7 | 16000497 | |
| RM-208 CB – 8 V ATEX | 24 V DC | |
- | 8 | 16000498 | |
| Product | Dust Ex Zone 22 |
Δp- sensor |
Number of valves |
P/N | |
|---|---|---|---|---|---|
| RM-208 C-VISIO 32 | 230 V AC / 110 V AC | - | |
0 | 16000389 |
| RM-208 CB-VISIO 32 | 230 V AC / 110 V AC | - | - | 0 | 16000409 |
| RM-208 C-VISIO 32 | 24 V DC | - | |
0 | 16000469 |
| RM-208 CB-VISIO 32 | 24 V DC | - | - | 0 | 16000489 |
| RM-208 C-VISIO 32 ATEX | 230 V AC / 110 V AC | |
|
0 | 16000399 |
| RM-208 CB-VISIO 32 ATEX | 230 V AC / 110 V AC | |
- | 0 | 16000419 |
| RM-208 C-VISIO 32 ATEX | 24 V DC | |
|
0 | 16000479 |
| RM-208 CB-VISIO 32 ATEX | 24 V DC | |
- | 0 | 16000499 |
| Product | Dust Ex Zone 22 |
Δp sensor |
Number of valves |
P/N | |
|---|---|---|---|---|---|
| RM-208 C with RM-LV 8 | 230 V AC / 110 V AC | - | |
9 | 16000420 |
| - | |
10 | 16000421 | ||
| - | |
11 | 16000422 | ||
| - | |
12 | 16000423 | ||
| - | |
13 | 16000424 | ||
| - | |
14 | 16000425 | ||
| - | |
15 | 16000426 | ||
| - | |
16 | 16000427 | ||
| RM-208 CB with RM-LV 8 | 230 V AC / 110 V AC | - | - | 9 | 16000440 |
| - | - | 10 | 16000441 | ||
| - | - | 11 | 16000442 | ||
| - | - | 12 | 16000443 | ||
| - | - | 13 | 16000444 | ||
| - | - | 14 | 16000445 | ||
| - | - | 15 | 16000446 | ||
| - | - | 16 | 16000447 | ||
| RM-208 C with RM-LV 8 | 24 V DC | - | |
9 | 16000500 |
| - | |
10 | 16000501 | ||
| - | |
11 | 16000502 | ||
| - | |
12 | 16000503 | ||
| - | |
13 | 16000504 | ||
| - | |
14 | 16000505 | ||
| - | |
15 | 16000506 | ||
| - | |
16 | 16000507 | ||
| RM-208 CB with RM-LV 8 | 24 V DC | - | - | 9 | 16000520 |
| - | - | 10 | 16000521 | ||
| - | - | 11 | 16000522 | ||
| - | - | 12 | 16000523 | ||
| - | - | 13 | 16000524 | ||
| - | - | 14 | 16000525 | ||
| - | - | 15 | 16000526 | ||
| - | - | 16 | 16000527 | ||
| Product | Dust Ex Zone 22 |
Δp sensor |
Number of valves |
P/N | |
|---|---|---|---|---|---|
| RM-208 C with RM-LV 8 ATEX | 230 V AC / 110 V AC | - | |
9 | 16000430 |
| - | |
10 | 16000431 | ||
| - | |
11 | 16000432 | ||
| - | |
12 | 16000433 | ||
| - | |
13 | 16000434 | ||
| - | |
14 | 16000435 | ||
| - | |
15 | 16000436 | ||
| - | |
16 | 16000437 | ||
| RM-208 CB with RM-LV 8 ATEX | 230 V AC / 110 V AC | - | - | 9 | 16000450 |
| - | - | 10 | 16000451 | ||
| - | - | 11 | 16000452 | ||
| - | - | 12 | 16000453 | ||
| - | - | 13 | 16000454 | ||
| - | - | 14 | 16000455 | ||
| - | - | 15 | 16000456 | ||
| - | - | 16 | 16000457 | ||
| RM-208 C with RM-LV 8 ATEX | 24 V DC | - | |
9 | 16000510 |
| - | |
10 | 16000511 | ||
| - | |
11 | 16000512 | ||
| - | |
12 | 16000513 | ||
| - | |
13 | 16000514 | ||
| - | |
14 | 16000515 | ||
| - | |
15 | 16000516 | ||
| - | |
16 | 16000517 | ||
| RM-208 CB with RM-LV 8 ATEX | 24 V DC | - | - | 9 | 16000530 |
| - | - | 10 | 16000531 | ||
| - | - | 11 | 16000532 | ||
| - | - | 12 | 16000533 | ||
| - | - | 13 | 16000534 | ||
| - | - | 14 | 16000535 | ||
| - | - | 15 | 16000536 | ||
| - | - | 16 | 16000537 | ||
| Product | Dust Ex Zone 22 |
Δp sensor |
Number of valves |
P/N |
|---|---|---|---|---|
| RM-216 C | - | |
0 | 16000300 |
| RM-216 CB | - | - | 0 | 16000320 |
| Product | Dust Ex Zone 22 |
Δp sensor |
Number of valves |
P/N |
|---|---|---|---|---|
| RM-216 C ATEX | |
|
0 | 16000310 |
| RM-216 CB ATEX | |
- | 0 | 16000330 |
| Product | Dust Ex Zone 22 |
Number of valves |
P/N |
|---|---|---|---|
| RM-LV 16 | - | 0 | 16000340 |
| RM-LV 8 - 0 V | - | 0 | 16000360 |
| RM-LV 16 ATEX | |
0 | 16000350 |
| RM-LV 8 - 0 V ATEX | |
0 | 16000370 |
| Product | Dust Ex Zone 22 |
Number of valves |
P/N |
|---|---|---|---|
| RM-LV 8 – 1 V | - | 1 | 16000361 |
| RM-LV 8 – 2 V | - | 2 | 16000362 |
| RM-LV 8 – 3 V | - | 3 | 16000363 |
| RM-LV 8 – 4 V | - | 4 | 16000364 |
| RM-LV 8 – 5 V | - | 5 | 16000365 |
| RM-LV 8 – 6 V | - | 6 | 16000366 |
| RM-LV 8 – 7 V | - | 7 | 16000367 |
| RM-LV 8 – 8 V | - | 8 | 16000368 |
| RM-LV 8 – 1 V ATEX | |
1 | 16000371 |
| RM-LV 8 – 2 V ATEX | |
2 | 16000372 |
| RM-LV 8 – 3 V ATEX | |
3 | 16000373 |
| RM-LV 8 – 4 V ATEX | |
4 | 16000374 |
| RM-LV 8 – 5 V ATEX | |
5 | 16000375 |
| RM-LV 8 – 6 V ATEX | |
6 | 16000376 |
| RM-LV 8 – 7 V ATEX | |
7 | 16000377 |
| RM-LV 8 – 8 V ATEX | |
8 | 16000378 |
| Product | Dust Ex Zone 22 |
Number of valves |
P/N |
|---|---|---|---|
| RM-LV 16 | - | 0 | 16000349 |
| RM-LV 8 | - | 0 | 16000369 |