BasicLine

Filter control system RM-CF

Function

The devices from the RM-CF BasicLine Series are compact switch cabinets for application in harsh industrial environments for small filter systems without or with pulse cleaning up to 4 valves.

Mains supply, power disconnection, motor connection and motor fuse protection take place using the components: main switch with emergency-off function, isolating transformer, power contactor and circuit breakers for the rated motor current. For filter systems with pulse cleaning the number of valves, valve opening time, pause time and downtime cleaning can be easily set via selector switch and jumper.

The device functions ON / OFF and the status messages ON / ALARM are realised via touch buttons and LEDs. Additional operating characteristics, external ON / OFF, cleaning start/stop, function alarm and start-up acknowledgement can be realised via signal inputs and potential-free relay outputs on the device.

In the EX version a temperature sensor monitors the device version with solenoid valves, shuts of the device in the event of malfunction and signals an alarm via a potential-free output.

Types

Two RM-CF and RM-CF 4 in different versions are available for the optimal application. In the RM-CF version no solenoid valves are integrated in the box, however, external solenoid valves may be connected if needed. The RM-CF-4 version is equipped with 1-4 integrated solenoid valves. Both types are designed for wall-mounting in the NormLine boxes.

The EX types for Zone 22, Cat. 3D are approved by DEKRA EXAM. In the RM-CF 4 version, a temperature sensor is installed to monitor the built-in solenoid valves.







No. Funktion Beschreibung
1 LED "ON" Signals the operation of the connected fan motor
2 LED "ALARM" Signal a fan alarm (tripping of the motor protection switch)
3 "ON" button Switches the fan on
4 "OFF" button Shuts off the fan and activates the set downtime cycles







Setting of number of valves

Jumper Number of
valves
JMP1JMP2
X X 1
- X 2
X - 3
- - 4

X   Jumper plugged in
–   Jumper pulled off



Setting of pause time

 Setting S3
0 1 2 3 4 5 6 7 8 9 A B C D E F
Setting
S2
0TMTMTMTMTMTMTMTMTMTMTMTMTMTMTMTM
1TM2 s4 s6 s8 s10 s12 s14 s16 s18 s20 s22 s24 s26 s28 s30 s
2TM3 s6 s9 s12 s15 s18 s21 s24 s27 s30 s33 s36 s39 s42 s45 s
3TM4 s8 s12 s16 s20 s24 s28 s32 s36 s40 s44 s48 s52 s56 s1 m
4TM10 s20 s30 s40 s50 s1 m1,2 m1,3 m1,5 m1,7 m1,8 m2 m2,2 m2,3 m2,5 m
5TM20 s40 s1 m1,3 m1,7 m2 m2,3 m2,7 m3 m3,3 m3,7 m4 m4,3 m4,7 m5 m
6TM30 s1 m1,5 m2 m2,5 m3 m3,5 m4 m4,5 m5 m5,5 m6 m6,5 m7 m7,5 m
7TM1 m2 m3 m4 m5 m6 m7 m8 m9 m10 m11 m12 m13 m14 m15 m
8TM2 m4 m6 m8 m10 m12 m14 m16 m18 m20 m22 m24 m26 m28 m30 m
9TM4 m8 m12 m16 m20 m24 m28 m32 m36 m40 m44 m48 m52 m56 m60 m
ATM---------------
BTM---------------
CTM---------------
DTM---------------
ETM---------------
FTM---------------

TM test mode (only for manufacturer), s seconds, m minutes


Product selection

Product Integrated
valves
Product No.
RM-CF 0,55 kW 0 32110200
1 32110201
2 32110202
3 32110203
4 32110204
RM-CF 0,75 kW 0 32110210
1 32110211
2 32110212
3 32110213
4 32110214
RM-CF 1,1 kW 0 32110220
1 32110221
2 32110222
3 32110223
4 32110224
RM-CF 1,5 kW 0 32110230
1 32110231
2 32110232
3 32110233
4 32110234
RM-CF 2,2 kW 0 32110240
1 32110241
2 32110242
3 32110243
4 32110244
RM-CF 3 kW 0 32110250
1 32110251
2 32110252
3 32110253
4 32110254
RM-CF 4 kW 0 32110260
1 32110261
2 32110262
3 32110263
4 32110264



To the top of the page